England GWDCD type outdoor high voltage isolation switch

GWDCD series outdoor high voltage isolation switch is a single phase hook bar with no load operation type switch. Used for AC 50Hz or 60Hz, rated voltage 12KV and below the overhead line, mainly used with circuit breakers or load switches, to provide a break, improve the safety of equipment operation and maintenance.

Product Description

Summarize

GWDCD series outdoor high voltage isolation switch is a single phase hook bar with no load operation type switch. Used for AC 50Hz or 60Hz, rated voltage 12KV and below the overhead line, mainly used with circuit breakers or load switches, to provide a break, improve the safety of equipment operation and maintenance. The on-line operating lever is used for the cut-and-close operation under no load.

Reference standard

GB 1985 "High voltage AC isolation switch and ground switch"

Use environment

1, the altitude does not exceed 1000m;
2, ambient air temperature :-10°C~45°C;
3, wind pressure does not exceed 700Pa(equivalent to wind speed 34m/s):
4, the maximum annual precipitation does not exceed 2400mm, the maximum monthly precipitation does not exceed 200mm;
5, the high daily temperature difference does not exceed 25K;
6, no frequent violent vibration places;
7. The installation site should be free of gases, vapors, chemical deposits, salt spray, dust and other explosive and corrosive substances that seriously affect the insulation and conductivity of the isolation switch

Product characteristics

1. The main circuit adopts 97% copper and silver plating treatment, which increases the electrical conductivity:
2, the pillar insulator adopts high-performance outdoor epoxy resin injection molding, corrosion resistance and outdoor anti-ultraviolet aging ability, strong hydrophobic performance, excellent process, creepage distance 367mm, pollution level IV V:
3, the limit pin can be adjusted 90° or 160° two limit modes, the factory mode is 160°, if you need 90° limit or no limit can be adjusted.

Technical parameter

Model number Rated voltage (kV) Rated current (A) 4S Thermal Stable current (RMS)(kA) Dynamic stable current (Peak)(KA) Impulse withstand voltage 1min power frequency withstand voltage
Relative to (kV) Interfracture (kv) Relative to (kV) Interfracture (kV)
(GW)DCD-121200 12 200 12.5 32 95 120 48 65
(GW)DCD-121400 12 400 12.5 32 95 120 48 65
(GW)DCD-12/630 12 630 20 50 95 120 48 65
(GW)DCD-121000 12 1000 31.5 80 95 120 48 65
(GW)DCD-121250 12 1250 31.5 80 95 120 48 65